Könyv 4D Image Verification Christian Schaller

4D Image Verification

Nyelv: Angol
Kötés: Puha kötésű
Kiadó: Grin Publishing
Elérhetőség: Beszállítói készleten
Küldés 9-15 napon belül
23 129 Ft
Diploma Thesis from the year 2007 in the subject Computer Science - Applied, grade: 1,0, Friedrich-A...

Információk a könyvről

Nyelv
Angol
Kötés
Könyv - Puha kötésű
Kiadva
2009
oldal
100
EAN
9783640333271
ISBN
3640333276
Enbook ID
01621036
Súly
141
Méretek
148 x 210 x 8

Teljes leírás

Diploma Thesis from the year 2007 in the subject Computer Science - Applied, grade: 1,0, Friedrich-Alexander University Erlangen-Nuremberg (Lehrstuhl für Mustererkennung), 66 entries in the bibliography, language: English, abstract: Far reaching developments and technical advances took place within the field of radiotherapy in the last years. Radiotherapy within the chest and abdomen area is especially important in the field of radiotherapy. Within this regions, organ and tumor positions are significantly affected by patient respiration. The tumor motion, caused due to respiration is compensated by extending the treated area. This extension covers all possible positions of the tumor and therefore also includes healthy tissue.Several clinical studies provide evidence of a survival advantage for higher dose levels. To spare a maximum of healthy tissue physicians use gated radiotherapy . Common recent approaches for gated radiotherapy are based on the observation of a surrogate. This either can be an implanted fiducial marker or an external signal, which is trying to capture the patients respiration.Within this thesis principles and methods of gated radiotherapy are described. Additionally an overview of recent patents and products related to radiotherapy are presented and advantages and disadvantages of both common approaches are discussed. This discussion leads to a new developed method, which is introduced. The method joins advantages of both known methods but disregards their disadvantages. The developed algorithm is using image guided methods and methods of medical image processing. A mapping between a 4D-CT planning volume and a most recent acquired fluoroscopic sequence of the same patient is calculated before treatment. Using this mapping and an external breathing signal the physician can define gating intervals and treat the patient in certain breathing phases.The developed algorithm is included in an existing prototype developed by Siemens Corporate Research (SCR) in Princeton, NJ, USA. Using this prototype, the application of the method is shown. Furthermore another prototype to acquire respiration synchronized fluoroscopic sequences is developed. Both applications are introduced within this thesis.

Érdekelheti

Obligation

Liu Jia
55 540 Ft

Is This My Love?

Gertrude E. Bridgeman Finney
7 886 Ft

Le Barbier de Séville, Ed. by A. Dobson

Pierre Augustin Caron De Beaumarchais
7 173 Ft

New Testament

G. H. Lee
7 657 Ft

Prelude to Galileo

William A. Wallace
19 327 Ft
1 652 Ft

Olympic Dream

Reinhard Kleist
5 893 Ft

Azok a vásárlók, akik ezt a könyvet megvásárolták, a következőket is megvásárolták

6 019 Ft
5 153 Ft

Rote Bete

Franziska von Au
3 443 Ft

Libera tus sombras

Kelly Bramblett
4 695 Ft